# Power Station vs Generator: 5-Year Cost Calculator

> Compare the true 5-year cost of a portable power station against a gas standby or portable generator: fuel, oil, maintenance, and replacement included.

- Source: https://batterygeneratorguide.com/tools/generator-cost/
- Markdown version: https://batterygeneratorguide.com/tools/generator-cost.md

---

- [Home](https://batterygeneratorguide.com/)
- [Tools](https://batterygeneratorguide.com/tools/)
- Generator cost comparison

# Power station vs generator: 5-year cost
A gas generator looks cheaper on the shelf — then you buy fuel, oil, and maintenance for five years. Enter your outage pattern and see the real total next to a comparable power station.

Power stationEcoFlow DELTA Pro 3 — ~$3,199–$3,699Anker SOLIX F3800 — ~$1,799–$3,999Jackery Explorer 2000 Plus — ~$2,399–$2,599BLUETTI Elite 200 V2 — ~$899–$1,499BLUETTI AC200L — ~$999–$1,599EcoFlow DELTA 2 Max — ~$1,099–$1,699Anker SOLIX F3000 — ~$1,399–$1,999Anker SOLIX C2000 Gen 2 — ~$899–$1,299Anker SOLIX C1000 — ~$399–$999EcoFlow DELTA 3 Plus — ~$799–$999DJI Power 1000 — ~$699–$999Jackery Explorer 1000 Plus — ~$899–$1,199BLUETTI Elite 300 — ~$1,199–$1,199BLUETTI Apex 300 — ~$1,699–$1,999EcoFlow DELTA 3 Max Plus — ~$1,149–$1,149Goal Zero Yeti 1500 (2026) — ~$1,499.95–$1,499.95BLUETTI Elite 100 V2 — ~$499–$499
Comparable gas generator price $900

Outage hours per year 48 h
Longest single outage you want covered 12 h

What you run during an outageEssentials: fridge, lights, router, chargers (~450 W)Half a house: plus a window AC or sump pump and TV (~1,800 W)Heavy: well pump, microwave, space heater too (~2,750 W)
Gasoline price $3.50/gal

## What the math includes
Gas generators burn fuel in proportion to the load, so the tool lets you pick what you run. We use published run-time specs: about 0.12 gal/hour at 450 W (Honda EU2200i, 8.1 hours on 0.95 gallons at a quarter load), 0.40 gal/hour at 1,800 W (Generac GP3600, 9.3 hours on 3.7 gallons at half load) and 0.61 gal/hour at 2,750 W (Generac GP5500, 11 hours on 6.7 gallons at half load). Add about $60 a year in oil, filters and spark plugs and a $300 wear-parts budget across five years. A power station costs only the electricity to recharge what you used, at 90% round-trip efficiency and $0.17 per kWh. No oil, no filters, no exercise runs.
Cost is only half the question. A station holds a fixed amount of energy, so the tool also shows how many hours one charge lasts at your load and whether that covers your longest outage. A generator runs as long as it has fuel. For the full breakdown of noise, fumes and maintenance, read our[power station vs standby generator](https://batterygeneratorguide.com/posts/power-station-vs-generator/) guide.

## A worked example
Use the starting values: essentials at about 450 W, 48 outage hours a year, a 12-hour longest outage, gasoline at $3.50 a gallon and a $900 generator, set against the EcoFlow DELTA 2 Max, a 2,048Wh station listed at about $1,099–$1,699. Forty-eight hours is a few storm outages a year, which is a plausible figure for a grid-connected home. These inputs are illustrative assumptions, not a recommendation.
For the generator: 48 h × 0.12 gal/h × $3.50 × 5 years is about $101 of fuel, and maintenance is $60 × 5 + $300 = $600. With the $900 purchase, the five-year total is about $1,601. For the station: the midpoint of its price range is $1,399. It uses 0.45 kW × 48 h × 5 years = 108 kWh, which is about 120 kWh drawn from the wall at 90% efficiency, or roughly $20 at $0.17 per kWh. That makes about $1,419 in total.
The station wins by about $182 on cost, a much thinner margin than a flat fuel-burn figure would suggest, because a small generator sipping fuel at a light load is cheap to run. The runtime check is where the trade-off shows: 2,048 Wh × 85% ÷ 450 W is about 3.9 hours per charge, so a 12-hour outage needs a bigger station, a second battery or solar. Switch the load to "half a house" and the generator's fuel bill rises to about $336 while a 2,400 W station runs about 1 hour per charge. This is illustrative math only, not a sizing or safety determination; have a licensed electrician size any generator or home backup connection.